Next: LAYER2/3 transputers
Up: ZEUS CALDAQ Transputer System
Previous: Standalone Test Runs
  Contents
For a description of the CSB crates and their function in the CALDAQ system
see chapter 2.5 and 3.5 of [4]; for a detailed description
of the CSB hardware see [5].
On the FCAL, BCAL and RCAL CSB the 64-pin connectors labelled
xCAL 2ND LEVEL TRIGGER-READOUT are numbered from 00 to 15 and
connect to the 2TP-modules in FCAL/BCAL/RCAL crates numbered 1 to 16
respectively.
Every socalled READOUT transputer of the connected 2TP-modules (the
2TP's Y-transputer) is connected
(internal to the CSB) to the ARE1- and the EVT1-board; the 2TP-modules
in crates 1 to 16 are connected to ARE1-0 to ARE1-15 and EVT1-0 to EVT1-15
respectively; the socalled TRIGGER transputers (the 2TP's X-transputers
are similarly connected to the ARE2- and EVT2-boards.
All connections labeled TRIG-n connect the TRIGGER transputer
in crate n+1 to LAYER2 of the Second Level Trigger transputer network;
see the transputer network scheme in appendix A.
Tables 9 to 15 give an overview of most of the rest
of the external LKS, ARE and EVT connections of the CSBs.
Table 9:
FCAL CSB LKS connections.
FCAL |
Connector |
Connected to link |
LKS1-SMLK |
TRP 1 |
LKS1-24 |
LKS2-24 |
LKS1-25 |
LKB-BMLK |
LKS1-26 |
FCAL ROCOLLECT 1 |
LKS1-27 |
FCAL ROCOLLECT 0 |
LKS1-28 |
FCAL MONITOR 1 |
LKS1-29 |
TEST-GSLT Y-1 |
LKS1-30 |
GSLT decision |
LKS2-SMLK |
TRP 2 |
LKS2-24 |
LKS1-24 |
LKS2-25 |
- |
LKS2-26 |
FCAL ROCOLLECT 2 |
LKS2-27 |
FCAL ROCOLLECT 3 |
LKS2-28 |
FCAL MONITOR 2 |
LKS2-29 |
REBOOTER 1 |
LKS2-30 |
- |
|
Table 10:
BCAL CSB LKS connections.
BCAL |
Connector |
Connected to link |
LKS1-SMLK |
TRP 1 |
LKS1-24 |
LKS2-24 |
LKS1-25 |
LKB-BMLK |
LKS1-26 |
BCAL ROCOLLECT 1 |
LKS1-27 |
BCAL ROCOLLECT 0 |
LKS1-28 |
BCAL MONITOR 1 |
LKS1-29 |
TEST-GSLT Y-2 |
LKS1-30 |
GSLT decision |
LKS2-SMLK |
TRP 2 |
LKS2-24 |
LKS1-24 |
LKS2-25 |
BCAL DATACOLLECT 1 |
LKS2-26 |
BCAL ROCOLLECT 2 |
LKS2-27 |
BCAL ROCOLLECT 3 |
LKS2-28 |
BCAL MONITOR 2 |
LKS2-29 |
REBOOTER 3 |
LKS2-30 |
TEST-GSLT X-0 |
|
Table 11:
RCAL CSB LKS connections.
RCAL |
Connector |
Connected to link |
LKS1-SMLK |
TRP 1 |
LKS1-24 |
LKS2-24 |
LKS1-25 |
LKB-BMLK |
LKS1-26 |
RCAL ROCOLLECT 1 |
LKS1-27 |
RCAL ROCOLLECT 0 |
LKS1-28 |
RCAL MONITOR 1 |
LKS1-29 |
TEST-GSLT Y-3 |
LKS1-30 |
GSLT decision |
LKS2-SMLK |
TRP 2 |
LKS2-24 |
LKS1-24 |
LKS2-25 |
- |
LKS2-26 |
RCAL ROCOLLECT 2 |
LKS2-27 |
RCAL ROCOLLECT 3 |
LKS2-28 |
RCAL MONITOR 2 |
LKS2-29 |
REBOOTER 2 |
LKS2-30 |
- |
|
Table 12:
BCAL CSB LKS3 (external LKS-board, located in BCAL SSC
(SubSystem Crate)) connections.
BCAL LKS3 |
Connector |
Connected to link |
LKS3-SMLK |
TRP 3 |
LKS3-00 |
LAYER3 0 |
LKS3-01 |
GSLT input |
LKS3-02 |
TEST-GSLT X-3 |
LKS3-04 |
- |
LKS3-05 |
- |
LKS3-06 |
- |
LKS3-07 |
- |
LKS3-08 |
- |
LKS3-09 |
- |
LKS3-10 |
- |
LKS3-11 |
- |
LKS3-12 |
- |
LKS3-13 |
- |
LKS3-14 |
- |
|
Table 13:
FCAL CSB ARE/EVT connections.
FCAL |
Connector |
Connected to transputer |
ARE3/EVT3-00 |
FCAL LAYER2 #0 |
ARE3/EVT3-01 |
FCAL LAYER2 #1 |
ARE3/EVT3-02 |
FCAL LAYER2 #2 |
ARE3/EVT3-03 |
FCAL LAYER2 #3 |
ARE3/EVT3-04 |
FCAL LAYER2 #4 |
ARE3/EVT3-05 |
FCAL MONITOR |
ARE3/EVT3-06 |
- |
ARE3/EVT3-07 |
- |
ARE3/EVT3-08 |
- |
ARE3/EVT3-09 |
- |
ARE3/EVT3-10 |
- |
ARE3/EVT3-11 |
- |
ARE3/EVT3-12 |
- |
ARE3/EVT3-13 |
- |
ARE3/EVT3-14 |
- |
ARE3/EVT3-15 |
FCAL ROCOLLECT |
|
Table 14:
BCAL CSB ARE/EVT connections.
BCAL |
Connector |
Connected to transputer |
ARE3/EVT3-00 |
BCAL LAYER2 #0 |
ARE3/EVT3-01 |
BCAL LAYER2 #1 |
ARE3/EVT3-02 |
BCAL LAYER2 #2 |
ARE3/EVT3-03 |
BCAL LAYER2 #3 |
ARE3/EVT3-04 |
BCAL LAYER2 #4 |
ARE3/EVT3-05 |
BCAL MONITOR |
ARE3/EVT3-06 |
BCAL DATACOLLECT |
ARE3/EVT3-07 |
DATACOLLECT |
ARE3/EVT3-08 |
- |
ARE3/EVT3-09 |
- |
ARE3/EVT3-10 |
- |
ARE3/EVT3-11 |
- |
ARE3/EVT3-12 |
- |
ARE3/EVT3-13 |
- |
ARE3/EVT3-14 |
TEST-GSLT |
ARE3/EVT3-15 |
BCAL ROCOLLECT |
|
Table 15:
RCAL CSB ARE/EVT connections.
RCAL |
Connector |
Connected to transputer |
ARE3/EVT3-00 |
RCAL LAYER2 #0 |
ARE3/EVT3-01 |
RCAL LAYER2 #1 |
ARE3/EVT3-02 |
- |
ARE3/EVT3-03 |
- |
ARE3/EVT3-04 |
- |
ARE3/EVT3-05 |
RCAL MONITOR |
ARE3/EVT3-06 |
MONITOR.HOST |
ARE3/EVT3-07 |
LAYER3 |
ARE3/EVT3-08 |
LAYER3 MONITOR |
ARE3/EVT3-09 |
- |
ARE3/EVT3-10 |
- |
ARE3/EVT3-11 |
- |
ARE3/EVT3-12 |
- |
ARE3/EVT3-13 |
- |
ARE3/EVT3-14 |
REBOOTER |
ARE3/EVT3-15 |
RCAL ROCOLLECT |
|
Next: LAYER2/3 transputers
Up: ZEUS CALDAQ Transputer System
Previous: Standalone Test Runs
  Contents
Henk Boterenbrood