next up previous contents
Next: Final State Positron vs. Up: Muon Candidate Finders Previous: Beampipe Halomuon Finder   Contents


Condensate Timing Based Finder

This muon finder looks for pairs of condensates which are far away from each other (distance of the condensate centers of more than ). It then calculates the velocity at which a particle would need to travel between the two condensates from the average condensate times. Then the candidate parameters are determined. If additional condensates are hit by the fitted trajectory they are added and the parameters are recalculated.

Candidates are vetoed if one of the following conditions is true:

  1. The event would still pass the trigger if the candidate cells were removed.
  2. The candidate contains a positron candidate (see section 6.7.6).

After calculating the muon candidate parameters at highest precision the user-supplied classification routine (see section 6.7.3) is called to positively identify the candidate.



Els de Wolf