WH/14/11/96 DATCHA specifications (collected from several sources) ====================================================== 1. High Voltage Channels. HV channels 2 channels/chamber 3 chambers means 3 x 2 = 6 HV channels. 4 channel/CAN node (2 CAN nodes needed) 2 CAN nodes/'QUAD_HV"-module (1 module needed) Specification per channel range 0 to 4095 Volt (set thru 12-bits DAC) ramping type linear speed software selectable in seconds (1-65535 sec) voltage monitoring 10-bits ADC; voltage automatically switched off by software in case of exceeding settable range noise ? ripple ? .... 2. Threshold settings. BIMUX threshold 0 to 250 mV 2 x threshold / chamber 3. Temperature measurement. 8 x wired sensors on tube, LM35 & cables. 10 bits range 0 to 4.096 V temperature sensors 100 mV/C range 0C to 40C 4. Masking noisy wires with BST register (32-bits BST-reg per BIMUX) BOL 16x32-bit register BML 14x32-bit register BIL 10x32-bit register individual masking per wire via (software) JTAG interface. 5. t0 ('tee-zero') calibration. select tube column [0:7] pulse toggle minimum pulse width 3 microseconds triggered by leading edge calibration tables with timing differences channels